Author: Caesar Wiratama
PT Tensor Karya Nusantara, wiratama@pt-tensor.com
Abstract. This report documents an OpenFOAM conjugate-heat-transfer validation of a laboratory-scale segmental baffle shell-and-tube heat exchanger (SG-STHX) used as the production baseline for the tensorSTHE template. A structured multi-region mesh (CFD-mesh01, ~1.45 M cells) is solved with chtMultiRegionSimpleFoam and RAS kOmegaSST. Heat transfer rate Q and shell-side pressure drop Δp are compared with Zahid et al. experiment only (Fig. 5) at five mass-flow rates ṁ = 0.027–0.047 kg/s. On the medium mesh, Δp errors remain within about 6–12% of experiment; Q improves from about −19% at the lowest ṁ to within a few percent at mid/high ṁ. A three-level GIT ladder is summarised with estimated coarse/fine errors. Mass-flow sensitivity recovers the experimental rise of Q and Δp with ṁ.
Cite: DOI 10.13140/RG.2.2.36572.35203
Publisher: Tensor Publisher